1.
Sensors (Basel) ; 24(8)2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38676267

RESUMO

The rapid increase in the number of vehicles has led to increasing traffic congestion, traffic accidents, and motor vehicle crime rates. The management of various parking lots has also become increasingly challenging. Vehicle-type recognition technology can reduce the workload of humans in vehicle management operations. Therefore, the application of image technology for vehicle-type recognition is of great significance for integrated traffic management. In this paper, an improved faster region with convolutional neural network features (Faster R-CNN) model was proposed for vehicle-type recognition. Firstly, the output features of different convolution layers were combined to improve the recognition accuracy. Then, the average precision (AP) of the recognition model was improved through the contextual features of the original image and the object bounding box optimization strategy. Finally, the comparison experiment used the vehicle image dataset of three vehicle types, including cars, sports utility vehicles (SUVs), and vans. The experimental results show that the improved recognition model can effectively identify vehicle types in the images. The AP of the three vehicle types is 83.2%, 79.2%, and 78.4%, respectively, and the mean average precision (mAP) is 1.7% higher than that of the traditional Faster R-CNN model.

2.
Front Neurosci ; 17: 1273686, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37811325

RESUMO

Image desmoking is a significant aspect of endoscopic image processing, effectively mitigating visual field obstructions without the need for additional surgical interventions. However, current smoke removal techniques tend to apply comprehensive video enhancement to all frames, encompassing both smoke-free and smoke-affected images, which not only escalates computational costs but also introduces potential noise during the enhancement of smoke-free images. In response to this challenge, this paper introduces an approach for classifying images that contain surgical smoke within endoscopic scenes. This classification method provides crucial target frame information for enhancing surgical smoke removal, improving the scientific robustness, and enhancing the real-time processing capabilities of image-based smoke removal method. The proposed endoscopic smoke image classification algorithm based on the improved Poolformer model, augments the model's capacity for endoscopic image feature extraction. This enhancement is achieved by transforming the Token Mixer within the encoder into a multi-branch structure akin to ConvNeXt, a pure convolutional neural network. Moreover, the conversion to a single-path topology during the prediction phase elevates processing speed. Experiments use the endoscopic dataset sourced from the Hamlyn Centre Laparoscopic/Endoscopic Video Dataset, augmented by Blender software rendering. The dataset comprises 3,800 training images and 1,200 test images, distributed in a 4:1 ratio of smoke-free to smoke-containing images. The outcomes affirm the superior performance of this paper's approach across multiple parameters. Comparative assessments against existing models, such as mobilenet_v3, efficientnet_b7, and ViT-B/16, substantiate that the proposed method excels in accuracy, sensitivity, and inference speed. Notably, when contrasted with the Poolformer_s12 network, the proposed method achieves a 2.3% enhancement in accuracy, an 8.2% boost in sensitivity, while incurring a mere 6.4 frames per second reduction in processing speed, maintaining 87 frames per second. The results authenticate the improved performance of the refined Poolformer model in endoscopic smoke image classification tasks. This advancement presents a lightweight yet effective solution for the automatic detection of smoke-containing images in endoscopy. This approach strikes a balance between the accuracy and real-time processing requirements of endoscopic image analysis, offering valuable insights for targeted desmoking process.

3.
Front Cardiovasc Med ; 9: 930745, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35958396

RESUMO

Background: Cardiovascular disease not only occurs in the elderly but also tends to become a common social health problem. Considering the fast pace of modern life, quantified heart rate variability (HRV) indicators combined with the convenience of wearable devices are of great significance for intelligent telemedicine. To quantify the changes in human mental state, this article proposes an improved differential threshold algorithm for R-wave detection and recognition of electrocardiogram (ECG) signals. Methods: HRV is a specific quantitative indicator of autonomic nerve regulation of the heart. The recognition rate is increased by improving the starting position of R wave and the time-window function of the traditional differential threshold method. The experimental platform is a wearable sign monitoring system constructed based on body area networks (BAN) technology. Analytic hierarchy process (AHP) is used to construct the mental stress assessment model, the weight judgment matrix is constructed according to the influence degree of HRV analysis parameters on mental stress, and the consistency check is carried out to obtain the weight value of the corresponding HRV analysis parameters. Results: Experimental results show that the recognition rate of R wave of real-time 5 min ECG data collected by this algorithm is >99%. The comprehensive index of HRV based on weight matrix can greatly reduce the deviation caused by the measurement error of each parameter. Compared with traditional characteristic wave recognition algorithms, the proposed algorithm simplifies the process, has high real-time performance, and is suitable for wearable analysis devices with low-configuration requirements. Conclusion: Our algorithm can describe the mental stress of the body quantitatively and meet the requirements of application demonstration.

4.
IEEE Trans Biomed Circuits Syst ; 12(1): 171-181, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29377805

RESUMO

Portable automatic seizure detection system is very convenient for epilepsy patients to carry. In order to make the system on-chip trainable with high efficiency and attain high detection accuracy, this paper presents a very large scale integration (VLSI) design based on the nonlinear support vector machine (SVM). The proposed design mainly consists of a feature extraction (FE) module and an SVM module. The FE module performs the three-level Daubechies discrete wavelet transform to fit the physiological bands of the electroencephalogram (EEG) signal and extracts the time-frequency domain features reflecting the nonstationary signal properties. The SVM module integrates the modified sequential minimal optimization algorithm with the table-driven-based Gaussian kernel to enable efficient on-chip learning. The presented design is verified on an Altera Cyclone II field-programmable gate array and tested using the two publicly available EEG datasets. Experiment results show that the designed VLSI system improves the detection accuracy and training efficiency.


Assuntos
Algoritmos , Eletroencefalografia , Aprendizado de Máquina , Convulsões/fisiopatologia , Processamento de Sinais Assistido por Computador/instrumentação , Dispositivos Eletrônicos Vestíveis , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Humanos
5.
Comput Math Methods Med ; 2017: 6849360, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28706561

RESUMO

An automatic detection system for distinguishing normal, ictal, and interictal electroencephalogram (EEG) signals is of great help in clinical practice. This paper presents a three-class classification system based on discrete wavelet transform (DWT) and the nonlinear sparse extreme learning machine (SELM) for epilepsy and epileptic seizure detection. Three-level lifting DWT using Daubechies order 4 wavelet is introduced to decompose EEG signals into delta, theta, alpha, and beta subbands. Considering classification accuracy and computational complexity, the maximum and standard deviation values of each subband are computed to create an eight-dimensional feature vector. After comparing five multiclass SELM strategies, the one-against-one strategy with the highest accuracy is chosen for the three-class classification system. The performance of the designed three-class classification system is tested with publicly available epilepsy dataset. The results show that the system achieves high enough classification accuracy by combining the SELM and DWT and reduces training and testing time by decreasing computational complexity and feature dimension. With excellent classification performance and low computation complexity, this three-class classification system can be utilized for practical epileptic EEG detection, and it offers great potentials for portable automatic epilepsy and seizure detection system in the future hardware implementation.


Assuntos
Diagnóstico por Computador , Epilepsia/diagnóstico , Convulsões/diagnóstico , Algoritmos , Eletroencefalografia , Humanos , Modelos Teóricos , Reprodutibilidade dos Testes , Análise de Ondaletas
SELEÇÃO DE REFERÊNCIAS